Incident Information:
Attachment Size Dudda Shop Unit 2 RX RLS.pdf (619.12 KB) 619.12 KB -
Location:
Florida -
Date:
01/28/2023 -
Incident Type:
EntrapmentUtility Task Vehicle (UTV) Incident -
Description:
Firefighters were conducting interior firing operations from a moving UTV on the Dudda Shop Prescribed Fire. The UTV operator executed a sudden halt to avoid a ditch. The UTV stalled and would not immediately start back up. Fire quickly impacted the UTV and both firefighters abandoned the UTV. An attempt was made to extinguish the fire using a fire extinguisher but the extinguisher was inoperable. One of the firefighters suffered minor burns to his nose, cheek, and legs. The UTV was destroyed by fire.